Building Regulations
  Summary of the Regulations
  Approved Documents
  Contraventions and Appeals
  Fees
 
The Approved Documents
 
Part B: Fire Safety
B1. Means of Escape All buildings have to be designed and constructed so that occupants can get out by their own means, without being overcome by fire and smoke and get to a place of safety outside the building. The design and positioning of doors, stairs corridors and windows constitutes the means of escape. In hospitals, nursing homes and other similar places where the occupants are not able to escape by their own unaided efforts special provisions are required.
 
B2. Internal Fire Spread (Linings) To inhibit the speed of which a fire accelerates through a building, the surfaces of ceilings and walls should be formed in materials which do not themselves burn easily and cause the rapid spread of flame.
 
B3. Internal Fire Spread (Structure) In the event of a fire a building should be designed and constructed so that its stability will be maintained for a reasonable period. The resistance to failure is increased by providing fire resistant construction. The length of time a building should resist collapse or contain a fire is specified according to the size and risk of the type of building. All building contain cavities that act like chimneys - if a fire gets inside concealed spaces it can spread undetected. Fire breaks need to be provided in these cavities to reduce the risk of fire spread.
 
B4. External Fire Spread Fire should not be able to spread or transfer from one building to another. By ensuring the stability of the external walls under fire conditions, reducing radiated heat by limiting window areas and preventing the use of materials that will allow the outside fabric of the building to burn.
 
B5. Access and Facilities for the Fire Service All buildings should be designed and constructed to ensure that in the event of a fire emergency the Fire Service can get to and operate their equipment within the building.
 
Click here for a downloadable version of the Approved Document Part B
Approved Document B (Fire safety) – Volume 1: Dwellinghouses (2006 Edition) (PDF 2217 Kb)
Approved Document B (Fire safety) – Volume 2 - Buildings other than dwellinghouses (2006 Edition, Amended 2007) (PDF 4876 Kb)
 
Archived Copies
 
Approved Document B - 2000 edition incorporating 2000 and 2002 amendments
Valid: 1st March 2003 - 6th April 2007
The requirements in this edition was:
B1 - Means of Warning and Escape
B2 - Internal fire spread (linings)
B3 - Internal Fire spread (structure)
B4 - External Fire spread
B5 - Access and facilities for the fire service
Approved Document B - Fire Safety (2000 Edition) (PDF 6.54Mb)
 
Approved Document B - 2002 amendments
Valid: 1st March 2003 - 6th April 2007
The requirements in this edition was:
B1 - Means of Warning and Escape
B2 - Internal fire spread (linings)
B3 - Internal Fire spread (structure)
B4 - External Fire spread
 
Approved Document B - Fire Safety (2000 Amendments) (PDF 342Kb)
 
Approved Document B - 2000 edition
Valid: 1st July 2000- 1st March 2003
The requirements in this edition was:
B1 - Means of Warning and Escape
B2 - Internal fire spread (linings)
B3 - Internal Fire spread (structure)
B4 - External Fire spread
B5 - Access and facilities for the fire service
Approved Document B - Fire Safety (2000 Edition) (PDF 1.72Mb)
 
Approved Document B - 1992 edition
Valid: 1st June 1992 - 1st July 2000
The requirements in this edition was:
B1 - Means of Warning and Escape
B2 - Internal fire spread (linings)
B3 - Internal Fire spread (structure)
B4 - External Fire spread
B5 - Access and facilities for the fire service
 
 
Mandatory rules for means of escape in case of fire - 1985 edition
Valid: 11th November 1985 - 1st June 1992
The requirements in this edition was:
B1 - Means of Warning and Escape
 
 
 
 
Mandatory Rules for Means of escape (1985 Edition) (PDF 1.3Mb)
 
Approved Document B - 1985 edition
Valid: 11th November 1985 - 1st June 1992
The requirements in this edition was:
B2/3/4 - Fire spread
 
 
 
 
 
 
 
 